Over-the-Side
Over-the-side heaters are ideal for heating water, oils, solvents, salts and acids. Over-the-side heater application versatility is enhanced with optional sheath materials, kilowatt ratings, terminal enclosures and mounting methods.
The L and O shaped “installed-from-the-top” heaters slide easily into tanks, with the heated portion immersed along the side or at the bottom. The drum immersion heaters are designed for direct immersion in a standard 55 gallon steel drum. Watlow® vertical loop immersion heaters are well-suited for open tank applications.
Specifications:
| Material | Maximum Operating Temperatures | Maximum Watt Densities | ||
|---|---|---|---|---|
| °F | °C | W/in2 | W/cm2 | |
| Alloy 800 | 1600 | 870 | 60 | 9.3 |
| N/A | 1400 | 760 | 43 | 6.7 |
| N/A | 750 | 400 | 23 | 3.6 |
| N/A | 1200 | 650 | 60 | 9.3 |
- Alloy 800 sheath element watt densities to 60 W/in² (9.3 W/cm²)
- Wattages to 50 killowatts
- Voltages to 600VAC
Applications:
- Water heating
- Freeze protection
- Viscous oils
- Storage tanks
- Degreasing tanks
- Solvents
- Salts
- Caustic solutions
- Paraffin
Features & Benefits:
| Features | Benefits |
|---|---|
| Rugged, light-weight construction |
|
| 0.475 in. (12 mm) diameter WATROD heating elements |
|
| WATROD hairpins are repressed (recompacted) |
|
| Four inch (100 mm) sludge legs |
|
| RTV riser seal |
|
| Standardized size 1 in. (25 mm) conduit openings |
|
| SRG insulated flexible lead wires, rated to 390°F (200°C) |
|
| Riser materials are compatible with element sheath materials such as stainless steel with Incoloy® sheath and steel with steel sheath |
|
| Circulation Heaters |
| 316 Stainless Steel Heaters |
| Duct Heaters |
| FIREBAR/Tubular Heaters |
| Flange Immersion Heaters |
| High Temperature Tubular Heater |
| MULTICOIL Tubular Heaters |
| Over-the-Side Immersion Heaters |
| Packaging Seal Bar Heaters |
| WATROD Tubular Heaters |
| Complete Thermal System Solutions for Plastics Processing |
| FIREBAR Heaters |
| Thermal Solutions for Foodservice Equipment |
| Thermal Solutions for Photovoltaic Processing Equipment |
| Watlow’s Heating Solutions For Your Applications |
| Heater Catalog (Section) – Immersion Heaters |
| Heater Catalog (Section) – Heater Reference Data |
| Heater Catalog (Section) – Agency Certifications |
| Heater Catalog (Complete – .pdf) |
| FIREBAR Flange Heater Installation & Maintenance Manual |
| FIREBAR Screw Plug Installation & Maintenance Manual |
| Thermostat Control Installation & Maintenance Manual |
| WATROD & FIREBAR Installation & Maintenance Manual |
| WATROD Circulation Heater Installation & Maintenance Manual |
| WATROD Duct Heater (Module Only) Installation & Maintenance Manual |
| WATROD Duct Heater Installation & Maintenance Manual |
| WATROD Flange Heater Installation & Maintenance Manual |
| WATROD Modular Duct Heater Installation & Maintenance Manual |
| WATROD Over-the-Side Installation & Maintenance Manual |
| WATROD Screw Plug Installation & Maintenance Manual |
| ISO 9001:2008 (2013-2016) Hannibal |
| Humidity Conditioning Requirements of Commercial Electric Cooking Appliances per UL 197 |